EcoTemp
EcoTemp WCA4364GKA 3 Ton 15 SEER Variable Speed EcoTemp Central Air Conditioner Split System - Multiposition - HA19770
EcoTemp WCA4364GKA 3 Ton 15 SEER Variable Speed EcoTemp Central Air Conditioner Split System - Multiposition - HA19770
Couldn't load pickup availability
Stay Cool Our Efficient And Durable Air Conditioning Units. Trust EcoTemp To Keep You Comfortable And Save You Money On Your Energy Bill.
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4364GKA Air Conditioner Features:
-
Air Conditioner
-
14 Seer
-
R-410A Refrigerant
-
1-5 Tons
-
Split System
-
208/230 Volt
-
1-Phase
-
60 Hz
WAXL364A Fan Coil Features:
-
Fan Coils
-
1.5-5 TON
-
600-2000 CFM
Specifications
Model | WCA4364GKA,WAXL364A |
---|---|
AHRI Number | 9529658 |
Bundle Avg Coverage Area | 1,500 - 1,800 Sq Ft |
Bundle Cooling Capacity | 3 Ton |
Bundle Cooling Efficiency | 15 SEER |
EER | 13 |
WCA4364GKASpecifications | |
Model | WCA4364GKA |
Avg Coverage Area | 1,500 - 1,800 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 3 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 30 amps |
Product Height (in) | 24.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 151.0000 |
WAXL364A Specifications | |
Model | WAXL364A |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 3 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 15 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.0625 |
Product Width (in) | 21.375 |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 157.0000 |
Additional Information
WCA4364GKA Air Conditioner
Refrigeration Circuit
-
Scroll compressors on all models
-
Copper tube / aluminum fin coil
Easy to Install and Service
-
Easy Access service valves on all models
-
External high and low refrigerant service ports
-
Only two screws to access control panel
-
Factory charged with R−410A refrigerant
Built to Last
-
Pre−painted cabinet finish over galvanized steel
-
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAXL364A Fan Coil
-
1−1/2 Thru 5 Tons
-
Environmentally Sound R−410a Systems
-
Multiposition Installation − Upflow Or Horizontal Left Standard.
-
Horizontal Right With Minor Modification.
-
Field Convertible To Downflow With Available Accessory Kit.
-
Txv Metering Device Factory Installed
-
Sweat Connections
-
Primary And Secondary Drain Fittings With Brass Inserts
-
3 Amp Automotive Type Fuse In Wire Harness
-
Multiple Electrical Entry Locations
-
Time Delay Relay (TDR) Programmed In Motor
-
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
-
Hud Approved For Manufactured Housing
-
208/230−1−60 Supply Voltage
-
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
-
1 Inch (25mm) Thick Insulation With R Value Of 4.2
-
Ecm Motor
-
No Heat (Plug) Kit Factory Installed
-
Filter (Washable) Factory Supplied
Product Manual
✓EcoTemp WCA4 Installation Manual
✓EcoTemp WCA4 Specification Manual
What Our Experts Think
- Energy-Efficient Cooling: With a 15 SEER rating, the EcoTemp WCA4364GKA ensures efficient cooling that reduces energy consumption while maintaining consistent comfort.
- Variable Speed Technology: The variable speed motor optimizes airflow based on cooling demand, ensuring smoother, quieter, and more efficient temperature control.
- 3-Ton Capacity: Ideal for larger homes or spaces requiring high-capacity cooling, providing ample performance across multiple rooms.
- Multiposition Installation: Offers flexible installation options, making it adaptable to various home layouts for easier and more versatile setup.
- Durability and Longevity: Designed with quality components for long-term performance, ensuring reliable, efficient cooling for years to come.
Q&A
Q: What is the EcoTemp WCA4364GKA 3 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4364GKA is a 3-ton, 15 SEER variable-speed central air conditioner split system, designed to provide efficient and consistent cooling for larger residential or light commercial spaces.
Q: What is SEER, and how does the 15 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 15 SEER rating ensures energy-efficient cooling, helping to reduce electricity bills while maintaining consistent comfort throughout the year.
Q: How does the variable-speed technology improve the system’s performance?
A: The variable-speed blower motor allows the system to adjust airflow based on cooling demands, leading to quieter operation, better humidity control, and improved energy efficiency.
Q: Can the EcoTemp WCA4364GKA be installed in various positions?
A: Yes, this air conditioner is a multiposition system, allowing for flexible installation in horizontal, vertical, or upflow configurations to accommodate different space requirements.
Q: Why should I choose the EcoTemp WCA4364GKA air conditioner?
A: The 15 SEER energy efficiency, variable-speed technology for enhanced comfort, and multiposition installation flexibility make the EcoTemp WCA4364GKA an excellent choice for cooling larger spaces efficiently and quietly.
Maintenance Tips
-
Replace or Clean Air Filters: Inspect air filters monthly, and replace or clean them every 1-3 months. Clogged filters impede airflow, reducing efficiency and increasing the workload on your system. Regular filter maintenance ensures optimal performance.
-
Clean the Coils: Clean the evaporator and condenser coils annually to prevent dirt and debris buildup, which can affect heat exchange and reduce the system’s cooling efficiency. Use a coil cleaner and a soft brush to remove debris gently.
-
Check Refrigerant Levels: Low refrigerant levels can cause poor cooling performance and lead to system failure. Schedule an annual checkup with a professional technician to ensure the refrigerant is at the appropriate level and to repair any leaks if necessary.
-
Clear Debris Around the Outdoor Unit: Keep the outdoor condenser unit clear of debris like leaves, dirt, and branches. Maintain at least a 2-foot clearance around the unit to ensure proper airflow and prevent the unit from overheating.
-
Inspect the Condensate Drain: Regularly check the condensate drain for blockages, as clogs can lead to water damage or mold growth. If necessary, clean the drain with a wet/dry vacuum to prevent backups.
-
Check Ductwork for Leaks: Inspect the ducts for any visible leaks, gaps, or disconnections. Leaky ducts waste energy and reduce cooling efficiency. Seal any gaps and schedule periodic duct cleaning to maintain proper airflow.
-
Test and Calibrate the Thermostat: Ensure the thermostat is correctly calibrated and maintains the desired temperature. Consider upgrading to a smart thermostat for better control over your cooling settings and improved energy efficiency.
-
Inspect Insulation: Check the insulation around the refrigerant lines and ducts for any damage or wear. Insulation prevents energy loss and ensures the system operates at peak efficiency, so repair or replace any damaged insulation as needed.
-
Ensure Proper Airflow: Ensure that all vents and registers are open and unobstructed by furniture or curtains. Blocked airflow can reduce the system’s cooling ability and cause it to work harder, lowering efficiency.
-
Schedule Professional Maintenance: Arrange for annual professional maintenance, ideally before the cooling season. A certified HVAC technician will clean the coils, inspect the refrigerant, check electrical components, and verify that the variable-speed system is operating at optimal performance.
Share


