EcoTemp
EcoTemp WCA4424GKA 3.5 Ton 14 SEER Multi Speed Central Air Conditioner Split System - Multiposition - HA19772
EcoTemp WCA4424GKA 3.5 Ton 14 SEER Multi Speed Central Air Conditioner Split System - Multiposition - HA19772
Couldn't load pickup availability
Stay Cool Our Efficient And Durable Air Conditioning Units. Trust EcoTemp To Keep You Comfortable And Save You Money On Your Energy Bill.
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4424GKA Air Conditioner Features:
-
Air Conditioner
-
14 Seer
-
R-410A Refrigerant
-
1-5 Tons
-
Split System
-
208/230 Volt
-
1-Phase
-
60 Hz
WAHL424B Fan Coil Features:
-
Fan Coils
-
1.5-5 TON
-
600-1750 CFM
Specifications
Model | WCA4424GKA,WAHL424B |
---|---|
AHRI Number | 9507436 |
Bundle Avg Coverage Area | 1,750 - 2,100 Sq Ft |
Bundle Cooling Capacity | 3.5 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 11.5 |
WCA4424GKA Specifications | |
Model | WCA4424GKA |
Avg Coverage Area | 1,750 - 2,100 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 3.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 35 amps |
Product Height (in) | 39.125 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 232.0000 |
WAHL424BSpecifications | |
Model | WAHL424B |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 3.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 20 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.06 |
Product Width (in) | 21.63 |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 157.0000 |
Additional Information
WCA4424GKA Air Conditioner
Refrigeration Circuit
-
Scroll compressors on all models
-
Copper tube / aluminum fin coil
Easy to Install and Service
-
Easy Access service valves on all models
-
External high and low refrigerant service ports
-
Only two screws to access control panel
-
Factory charged with R−410A refrigerant
Built to Last
-
Pre−painted cabinet finish over galvanized steel
-
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAHL424B Fan Coil
-
1−1/2 Thru 5 Tons
-
Available For Environmentally Sound R−410a Systems
-
Factory Installed Txv Metering Device
-
Sweat Connections
-
Aluminum Tube, Aluminum Fin Evaporator
-
Primary And Secondary Drain Fittings
-
Multiple Electrical Entry Locations
-
Time Delay Relay (TDR)
-
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
-
Hud Approved For Manufactured Housing
-
208/230−1−60 Supply Voltage
-
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
-
1 Inch Thick Insulation With R Value Of 4.2
-
Filter (Washable) Available As Accessory
-
Ecm 5−speed Motor
-
Multiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field
-
Convertible To Downflow With Available Accessory Kit)
-
Low Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness
-
No Heat (Plug) Kit Factory Installed
Product Manual
✓EcoTemp WCA4 Installation Manual
✓EcoTemp WCA4 Specification Manual
What Our Experts Think
- Reliable Cooling Efficiency: With a 14 SEER rating, the EcoTemp WCA4424GKA offers solid cooling performance while keeping energy costs low, making it an economical choice for your home.
- 3.5-Ton Capacity: Perfect for larger homes or spaces, providing ample cooling power to efficiently manage temperature across multiple rooms.
- Multi-Speed Operation: The multi-speed functionality allows for customizable airflow, adapting to your cooling needs for better comfort and control.
- Flexible Installation: The multiposition design ensures easy and versatile installation, accommodating various home layouts for a seamless setup.
- Durable Construction: Built with high-quality materials, this system is designed for long-term reliability and consistent performance, even under heavy use.
Q&A
Q: What is the EcoTemp WCA4424GKA 3.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4424GKA is a 3.5-ton, 14 SEER multi-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.
Q: What is SEER, and what benefits does the 14 SEER rating offer?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14 SEER rating ensures that the system delivers reliable and cost-effective cooling while helping to reduce energy consumption compared to lower-rated units.
Q: What advantages does the multi-speed functionality provide?
A: The multi-speed blower motor adjusts airflow based on cooling demands, ensuring quieter operation, better comfort, and increased energy efficiency.
Q: Can the EcoTemp WCA4424GKA be installed in different positions?
A: Yes, this system is multiposition, offering flexibility to install it in horizontal, vertical, or upflow configurations, depending on your space and layout needs.
Q: Why should I choose the EcoTemp WCA4424GKA air conditioner?
A: With its 14 SEER energy efficiency, multi-speed functionality for improved comfort, and versatile multiposition installation, the EcoTemp WCA4424GKA is an ideal solution for efficiently cooling larger spaces.
Maintenance Tips
-
Replace or Clean Air Filters: Check air filters every month and clean or replace them every 1-3 months. Clogged filters impede airflow, reduce system efficiency, and can cause strain on the system, leading to overheating or premature failure.
-
Clean Evaporator and Condenser Coils: Clean both the evaporator and condenser coils at least once a year. Dirt and debris accumulation on the coils can cause poor heat transfer and affect the system's efficiency. Use a coil cleaner and a soft brush to remove buildup.
-
Check Refrigerant Levels: Have a licensed technician check the refrigerant levels annually. Low refrigerant levels can reduce cooling performance and damage the compressor. Ensure the system is properly charged with refrigerant.
-
Clear Outdoor Unit of Debris: Maintain at least a 2-foot clearance around the outdoor unit to allow proper airflow. Remove leaves, dirt, and other debris that could block airflow, prevent heat dissipation, and cause overheating.
-
Inspect the Condensate Drain: Regularly inspect the condensate drain for blockages. A clogged drain can lead to water damage, mold growth, or poor system performance. Clear the drain line using a wet/dry vacuum or pipe cleaner if needed.
-
Inspect Ductwork for Leaks: Leaky or disconnected ducts can reduce cooling efficiency and increase energy consumption. Inspect ductwork for leaks, gaps, or damage, and seal any visible issues. Consider having ducts cleaned periodically to optimize airflow.
-
Test and Calibrate the Thermostat: Ensure the thermostat is functioning correctly and maintains a consistent temperature. If your system uses a programmable thermostat, adjust it for better control and energy savings. A smart thermostat can provide more flexibility and efficiency.
-
Check Insulation: Inspect the insulation around refrigerant lines and ducts. Damaged insulation can lead to energy loss, causing the system to work harder. Replace any worn or damaged insulation to maintain optimal performance.
-
Ensure Proper Airflow: Ensure that all supply and return vents are open and unobstructed by furniture or curtains. Blocked airflow can reduce system efficiency, leading to higher energy consumption and strain on the system.
-
Schedule Annual Professional Maintenance: Arrange for an annual professional inspection to ensure your EcoTemp system is operating efficiently. A technician can clean the coils, check refrigerant levels, inspect the blower, and ensure the multi-speed system is functioning optimally.
Share


